Device/label sampling target list screen

Devices and labels specified as sampling targets for the device/label batch specification and the device individual
specification are listed.
Window
Click the [Device/Label Sampling Target List] button in "Device/Label Sampling Target Setting."
Displayed items
Item
Sampling Target Device List
Sampling Target Label Size List
Sampling Size (Overall)
*1 Displayed in red and a warning icon appears in any of the following cases:
An unconverted program is included in a target program when the device/label batch specification is enabled.
A target program exists in the program setting in the CPU parameter but not in the navigation window when the device/label batch
specification is enabled.
A local device in a program that is unconverted or does not exist is specified as a sampling target in the "Device Individual Specification"
screen.
3 RECORDING SETTING
60
3.3 Device/Label Sampling Setting
Device/Local Device
Start Device
End Device
Points (Decimal)
Size [Word]
Label Type
Size [Word]
Description
Sampling target devices are listed.
• If a sampling target is specified for multiple specification methods, it is
displayed without duplication.
(Example) When specifying D0 to D31 for the device/label batch
specification and the device individual specification, they are displayed for
one of the methods only.
• A device is not displayed if "-" is displayed in "Sampling Target" for the
device individual specification.
• If ranges of devices to be sampled are continuous or overlap, they are
displayed as one range.
(Example) When specifying D0 to D31 for the device/label batch
specification and D32 to D95 for the device individual specification, D0 to
D95 are displayed.
The type of a device is displayed.
For a local device, a program to which the device belongs is also displayed.
The start of devices to be sampled is displayed.
The end of devices to be sampled is displayed.
The number of device points to be sampled is displayed.
The size of a device to be sampled is displayed.
The total size of labels to be sampled is displayed for each type.
The type is displayed.
The total size is displayed.
The total size of devices and labels to be sampled is displayed.
*1