If "Save Device/Label Operations" is set in the event history setting of the CPU parameter, the event history is saved when a
device/label operation is performed from an external device.
It is automatically set to "Save" when the camera recorder module is added to the system configuration and the parameters
are confirmed.
Page 24 Creating a New Project
[CPU Parameter] [RAS Setting] [Event History Setting]
Since the data memory has a limited number of write cycles, the save destination is set to the memory card in
this guide.
For details on the event history setting, refer to the following.
MELSEC iQ-R CPU Module User's Manual (Application)
APPX
93
Appendix 2 Event History Function (Saving Device/Label Operations)
Event History Function (Saving Device/
Label Operations)