Device individual specification screen

Devices can be specified individually.
Window
Click the [Setting] button next to "Device Individual Specification" in "Device/Label Sampling Target Setting."
Displayed items
Item
Device individual
*1
specification list
Device/Local Device
Start Device
End Device
Points (Decimal)
Sampling Target
Size [Word]
Sampling Size (Device Individual Specification)
*1 Up to 65536 rows can be set.
*2 Displayed in red in either of the following cases:
No program file is registered for the corresponding execution program number.
A program file registered for the corresponding execution program number is unconverted.
*3 Can be set unless the cell in "Device/Local Device" is blank.
*4 Displayed in red in either of the following cases:
The device is smaller than the start device set in the CPU parameter.
The device is larger than the end device set in the CPU parameter.
*5 Can be set if the cell in "Start Device" is not blank and "Start/End" is selected for "Setting Method."
*6 Can be set if the cell in "Start Device" is not blank and "Points/Start" is selected for "Setting Method."
*7 "-" is displayed in the following cases:
Some items are not entered.
No program file is registered for the corresponding execution program number for a local device.
A program file registered for the corresponding execution program number is unconverted for a local device.
A device that is not set as available in the CPU parameter is specified.
The device range set in the CPU parameter is out of the range of the start to end devices.
*8 Displayed in red and a warning icon appears in either of the following cases:
A local device for which no program file is registered for the corresponding execution program number is specified.
A local device for which a program file registered for the corresponding execution program number is unconverted is specified.
Description
Specify a device.
The following two types of setting methods are available and can be switched by right-clicking and
selecting [Setting Method]  [Start/End] or [Points/Start].
• Start/End: To set the start and end devices to automatically acquire the number of points.
• Points/Start: To set the start device and the number of points to automatically acquire the end
device.
When entering a device corresponding to the current value of a timer or counter, a coil, or contact, it
is replaced with its basic device symbol.
Select the type of a device (local device or global device).
For a local device, also select a program to which the device belongs.
Specify the start of devices to be sampled.
Specify the end of devices to be sampled.
Specify the number of device points to be sampled.
The range of devices to be sampled is displayed based on the sampling unit.
For the sampling unit of each device, refer to the following:
Page 24 Devices and labels that can be sampled
The size of a device to be sampled is displayed.
The total size of devices to be sampled specified for the device individual specification is displayed.
*2
*3,*4
*4,*5
*6
*7
3 RECORDING SETTING
3.3 Device/Label Sampling Setting
3
*8
57