Errors Between Ae-200 And Ae-50 (Ew-50) - Mitsubishi Electric AE-200A Instruction Book

Air conditioning control system centralized controller
Hide thumbs Also See for AE-200A:
Table of Contents

Advertisement

6810
Communication error - UR communication error
6811
Communication error - UR communication synchronism not recover
6812
Communication error - UR communication hardware error
6813
Communication error - UR communication status bit detection error
6820
Other communication errors
6821
Other communication errors - Transmission line busy
6822
Other communication errors - No communication ACK
6823
Other communication errors - No response command
6824
Other communication errors - Receive data error
6830
Communication error - MA communication refrigerant address double setting error
6831
Communication error - No MA communication reception error
6832
Communication error - MA communication synchronism not recover
6833
Communication error - MA communication transmission/reception hardware trouble
6834
Communication error - MA communication start bit detection error
6840
Communication error - A control no indoor/outdoor communication/reception abnormality
6841
Communication error - A control indoor/outdoor communication synchronization recovery abnormal
6842
Communication error - A control indoor/outdoor communication - Communication H/W abnormality
6843
Communication error - A control indoor/outdoor communication - Start bit detection abnormality
6844
Communication error - A control indoor/outdoor communication incorrect indoor/outdoor wiring connection, excessive number of indoor
units (more than five units)
6845
Communication error - A control indoor/outdoor communication incorrect indoor/outdoor wiring connection (telecommunication,
disconnection)
6846
Communication error - A control indoor/outdoor communication startup time exceeded
7000
System abnormality
7100
System abnormality - Total capacity error
7101
System abnormality - Capacity code error
7102
System abnormality - Connecting unit number excess
7103
System abnormality - Piping length setting error
7104
System abnormality - Floor height setting error
7105
System abnormality - Address setting over 254
7106
System abnormality - Attribute setting error
7107
System abnormality - Distributor setting error
7108
System abnormality - Refrigerant system setting error
7109
System abnormality - Connection setting error
7110
System abnormality - Refrigerant system connection/connection data unsettled
7111
System abnormality - I/O connection equipment not connected/remote controller sensor abnormality
7112
System abnormality - I/O type setting error
7113
System abnormality - Equipment unsettled
7114
System abnormality - Too many VAV units
7115
System abnormality - Too many units requiring ventilation
7116
System abnormality - Replace non-wash setting error
7117
System abnormality - Model identification setting error
7130
System abnormality - Different unit model error
7131
System abnormality - Mixed cooling only H/P connection error (Facility PAC)
7132
System abnormality - Multiple entries of operation performance (Facility PAC)
7200
System abnormality - Numeric values unsettled
7201
System abnormality - Numeric values unsettled
73**
System abnormality - LON system equipment abnormality

3-6-2. Errors between AE-200 and AE-50 (EW-50)

6920
Communication error - No response error
6922
Communication error - Receiving frame ID error
7901
System abnormality - Excessive number of connected units
7902
System abnormality - Connection lock error
7903
System abnormality - Unit information error
7904
System abnormality - System setting error
7905
System abnormality - Version error/Different unit model error
WT07992X02