Mitsubishi Electric AE-200A Instruction Book page 70

Air conditioning control system centralized controller
Hide thumbs Also See for AE-200A:
Table of Contents

Advertisement

Item
[Data type: 1-day intervals]
Row
1st
2nd
3rd
4th
Energy
management
data
5th–
779th
*1 The numbers shown after "MCP" and "MCT" indicate channel No.
*2 The numbers in the parentheses indicate M-NET addresses.
*3 The M-NET address indicated in the parentheses will not appear for the measurement data of the built-in Pulse Input
(PI).
*4 The measurement unit for MCP (PI controller) will be the measurement unit that has been set on the [Measurement]
screen. (Refer to the Instruction Book (Initial Settings) for details.)
*5 The measurement item for MCT (AI controller) will be temperature or humidity, which has been set on the
[Measurement] screen. (Refer to the Instruction Book (Initial Settings) for details.)
*6 "Outdoor temperature," "Cooling set temperature," "Heating set temperature," and "Room temperature" in the data
are the average daily values of the temperature values obtained every hour.
*7 "MCT 1" and "MCT 2" in the data are the average daily temperature or humidity values obtained every hour.
*8 The value will not appear if the data does not exist.
*9 Each file contains up to 775 data (25-month worth of data).
WT07992X02
Item
File Type
503
Data range
Start date + "–" + End date
"Date,Data1(51),...Data1(100),Data3(51),...Data3(100),
OutdoorTemp(51),...OutdoorTemp(100),CoolSetTemp(1),...CoolSetTemp(50),
HeatSetTemp(1),...HeatSetTemp(50),RoomTemp(1),...RoomTemp(50),
FanTime(1),...FanTime(50),CoolTime(1),...CoolTime(50),
HeatTime(1),...HeatTime(50),ThermoTime(1),...ThermoTime(50),
CoolThermoTime(1),...CoolThermoTime(50),
HeatThermoTime(1),...HeatThermoTime(50),
Item
*1*2
SaveValue(1),...SaveValue(50),CoolSaveValue(1),...CoolSaveValue(50),
HeatSaveValue(1),...HeatSaveValue(50),
ApporionedElectricEnergy(1),...ApporionedElectricEnergy(50),
TargetElectricEnergy(1),...TargetElectricEnergy(50),
MCP1(0),...MCP1(50),MCP2(0),...MCP2(50),MCP3(0),...MCP3(50),
MCP4(0),...MCP4(50),MCT1(1),...MCT1(50),MCT2(1),...MCT2(50),
AHC1(201),...AHC1(250),AHC2(201),...AHC2(250),
MCP1,MCP2,MCP3,MCP4
ApportionedElectricEnergy, TargetElectricEnergy
Data1, Data3
OutdoorTemp, CoolSetTemp, HeatSetTemp,
RoomTemp
Measurement
FanTime, CoolTime, HeatTime, ThermoTime,
*4*5
unit
CoolThermoTime, HeatThermoTime, SaveValue,
CoolSaveValue, HeatSaveValue
MCP (PI controller/Built-in Pulse Input (PI))
MCT (AI controller)
AHC (Advanced HVAC CONTROLLER)
Date, Data 1 (51), ... (100), Data 3 (51), ... (100),
Outdoor temperature (51), ... (100), Cooling set temperature (1), ... (50),
Heating set temperature (1), ... (50), Room temperature (1), ... (50),
Fan operation time (1), ... (50), Cooling operation time (1), ... (50),
Heating operation time (1), ... (50), Thermo-ON time (1), ... (50),
Data
Cooling Thermo-ON time (1), ... (50), Heating Thermo-ON time (1), ... (50),
Capacity-save value (1), ... (50), Cooling capacity-save value (1), ... (50),
*1*2*6*7*8*9
Heating capacity-save value (1), ... (50), Apporioned electric energy (1), ... (50),
Target electric energy (1), ... (50), MCP 1 (1), ... (50), MCP 2 (1), ... (50),
MCP 3 (1), ... (50), MCP 4 (1), ... (50), MCT 1 (1), ... (50), MCT 2 (1), ... (50),
AHC temperature 1 (201), ... (250), AHC temperature 2 (201), ... (250), MCP 1, MCP
2, MCP 3, MCP 4
Description
Format
*3
"
Item
70
Unit
kWh
-
ºC, ºF
Minute
kWh, m3, MJ
ºC, ºF, %
ºC, ºF