SINAMICS S120 is now again in the delivery status and all parameters and
BICO interconnections are reset to factory settings.
The connected modules of SINAMICS S120 are now no longer included in
the configuration and have to be recommissioned.
V1.0
Instruction
Edition 10/28/05
Commissioning SINAMICS S120
Preparing SINAMICS S120
Note
Acknowledge the query by clicking
OK.
The Save factory settings to ROM
function has to be set. If it is not set,
the Copy RAM to ROM function
must be activated after loading the
factory settings to the RAM!
Successful restoring of the factory
settings is indicated by the The
factory settings have been
restored message.
The opposite message indicates the
permanent storage of the settings
on the compact flash card.
Terminate the online connection by
selecting the menu item
Disconnect from target system.
Close the S7T Config configuration
tool by clicking Exit.