Ambient conditions
Environmental limits for the drive are given below. The drive is to be used in a heated,
indoor, controlled environment.
Installation site altitude
Air temperature
Relative humidity
Contamination
Vibration
IEC/EN 61800-5-1
IEC 60068-2-6:2007,
EN 60068-2-6:2008 Envir-
onmental testing Part 2:
Tests –Test Fc: Vibration
(sinusoidal)
Shock
IEC 60068-2-27:2008, EN
60068-2-27:2009
Environmental testing -
Part 2-27: Tests - Test Ea
and guidance: Shock
Operation
installed for stationary
use
0...2000 m (0...6562 ft)
above sea level. For alti-
tudes over 2000 m, contact
ABB.
Output derated above 1000
m (3281 ft).
0 ... +45 °C
(+32 ... +113 °F), no con-
densation allowed. Output
derated in the range
+45 ... +55 °C
(+113 ... +131 °F).
Max. 95%
No condensation allowed. Maximum allowed relative humidity is 60% in the presence
IEC/EN 60721-3-3:2002:
Classification of environ-
mental conditions - Part 3-
3: Classification of groups
of environmental paramet-
ers and their severities -
Stationary use of weather
protected locations
Chemical gases: Class
3C2
Solid particles: Class 3S2.
No conductive dust al-
lowed.
IEC/EN 60721-3-3:2002
10...57 Hz: max. 0.075 mm
amplitude
57...150 Hz: 1 g
Units with marine construc-
tion (option +C121): Max.
1 mm (0.04 in)
(5 ... 13.2 Hz), max. 0.7 g
(13.2 ... 100 Hz) sinusoidal
Not allowed
Storage
in the protective package
-
-40 to +70 °C (-
40 to +158 °F)
Max. 95%
of corrosive gases.
IEC 60721-3-1:1997
Chemical gases: Class
1C2
Solid particles: Class 1S3
(packing must support this,
otherwise 1S2)
IEC/EN 60721-3-1:1997
10...57 Hz: max. 0.075 mm
amplitude
57...150 Hz: 1 g
With packing max.
2
2
100 m/s
(328 ft/s
) 11 ms
Technical data 105
Transportation
in the protective package
-
-40 to +70 °C (-
40 to +158 °F)
Max. 95%
IEC 60721-3-2:1997
Chemical gases: Class
2C2
Solid particles: Class 2S2
IEC/EN 60721-3-2:1997
2...9 Hz: max. 3.5 mm
amplitude
2
9...200 Hz: 10 m/s
2
(32.8 ft/s
)
With packing max.
2
2
100 m/s
(328 ft/s
) 11 ms