Fixing RRH
To fix RRH_1 Sector Wall Type (Standard & Side Installation)
Make sure you have the following items:
1
Table 21. Fixing RRH_1 Sector Wall Type (Standard & Side Installation)
Category
Description
Parts
M10 × L35 Hex. Bolt (washer assembly,
attached to the unit bracket)
Recommended Torque Value
M10 Hex. Bolt
Working Tools
Torque Wrench (100~400 lbf·in)
Torque Wrench Spanner head (apply Hexagon Head: 17 mm)
Spanner (17 mm)
Hang the unit bracket hook of RRH side on the mounting bracket_front hook's
2
groove and fix it using fasteners.
Figure 56. Fixing RRH_1 Sector Wall Type (Standard Installation)
1
2
RF4402d Series Installation Manual v1.0
Copyright © 2018, All Rights Reserved.
Chapter 2 Installing System
1 EA
217 lbfin
Unit Bracket Hook
Mounting Bracket_Front
Hook Groove
M10 Hex. Bolt
(washer assembly)
Confidential
59