11. Install and tighten the two M4×12 (T20) screws.

Power cabinet cooling fan replacement

1. Read and repeat the steps in
2. Open the cabinet doors of stator part.
3. Disconnect the fan wiring plug.
4. Remove four screws.
5. Pull the fan out.
6. Check the cleanliness of the cabinet. Clean the interior of the cabinet if necessary
using a soft brush and a vacuum cleaner.
7. Install a new fan in reverse order.

ALCL filter fan replacement

1. Read and repeat the steps in
2. Open the cabinet doors.
3. Disconnect the fan wiring plug (1).