ABB ACS800 Series Hardware Manual page 79

+c236 wind turbine convert for asynchronous slip ring generators
Hide thumbs Also See for ACS800 Series:
Table of Contents

Advertisement

79
(9) Extend the support legs of the module. Keep the legs extended until the module is about to be inserted back into the
cabinet.
9a
9b
LCL filter module:
(10) Disconnect the L-shaped AC busbars on top of the filter module: Loosen the three upper screws (10a), but leave
them in place. Remove the three lower screws (10b).
(11) Disconnect the socket terminal block next to the AC busbars.
(12) Remove the two module fastening screws at the top.
(13) Remove the fan: Disconnect the fan wiring plug (13a). Remove the locking screw (13b). Pull the fan out along its
sliding rails (13c).
(14) At the base of the module, remove the four fastening screws.
(15) Latch the module ramp to the hook at the base of the cabinet.
(16) Pull the module carefully out of the cabinet along the ramp.
ALCL
10a
13a
10b
13b
12
13c
11
BLCL
16
14
13a
13c
15
Lead the cables into the cabinet.
Electrical installation