Setting Normal Recording Area Overwriting And Remaining Capacity On The Operation Display Area - Sanyo DSR - 300 Instruction Manual

Digital video recorder
Table of Contents

Advertisement

4
RECORDING CONDITIONS SET
Setting normal recording area
overwriting and remaining capacity
on the operation display area
Settings can be made to indicate whether overwriting is to
be performed (deleting old images) recording is to be
stopped when any of the hard disk's recording areas
become full. In the latter case, the remaining capacity is
shown as a percentage on the operation display area.
1
Move the cursor to "OVERWRITE"
under "NORMAL RECORDING AREA"
and press the [ ] button, then press the
[
] or [
] button to select "OFF".
"**" from "REMAINING DISK WARNING" changes to "1%".
[Settings] (
indicates default setting.)
Setting
Recording is stopped when the normal recording
OFF
area becomes full.
Overwriting automatically starts from the beginning
ON
of the normal recording area when it becomes full.
2
Press the [ ] button.
The cursor moves to "OVERWRITE" for the alarm
recording area.
If this setting is turned "OFF", the space warning or
ALARM FULL indicator will start to flash when the
remaining hard-disk capacity reaches the percentage
set for "REMAINING DISK WARNING".
English
Description
3
Press the [ ] button, then press the [
or [
] button to select "OFF".
[Settings] (
indicates default setting.)
Setting
Recording is stopped when the alarm recording
OFF
area becomes full.
Overwriting automatically starts from the beginning
ON
of the alarm recording area when it becomes full.
Each menu setting should be performed for each
individual unit.
4
Press the [ ] button to move the cursor
to "REMAINING DISK WARNING" and
press the [ ] button, then press the [
or [
] button to select a remaining
capacity value.
(Example: 5%)
The remaining capacity can be set anywhere between 1%
(default) and 10%.
5
Press the [EXIT/OSD] button.
The display returns to the normal screen.
A warning will be displayed in the operation display area
when the remaining capacity for any recording area
reaches setting value. In addition, the ALARM indicator
(for the normal recording area) or the ALARM FULL
indicator (for the alarm recording area) will flash at this
time.
FULL indicator
Operation
display area
10-20-04 ALARM 0000
08:30:00 EN
57
]
Description
]
ALARM FULL indicator
Remaining
5%
capacity
display
10FPS