INTERFACE SPECIFICATIONS
(when optional interface board is installed)
Commands for setting the recorder
CLOCK ADJUST (E0H)
If sent with the recorder stopped, resets the minutes
and seconds of the clock display to 00. For example,
if sent between 13:30:00 and 14:29:59, sets the
clock to 14:00:00.
On-screen commands
MENU (74H)
If sent with the recorder stopped, displays the main
menu.
If sent with a sub-menu displayed, toggles the menu
screen each time it is sent.
/CLEAR (53H)
If sent while a menu screen is displayed, sets the
setting item selection or value.
If sent while the main menu is displayed, switches to
the selected sub-menu.
If sent while a data display is on screen, moves the
display to the left. No operation is performed if sent
during recording.
Starts rewinding.
If sent during playback, starts rewind playback.
If sent during still mode, rewinds the image by one
frame (field).
/ENTER (63H)
If sent while a menu screen is displayed, sets the
setting item selection or value.
If sent while the main menu is displayed, switches to
the selected sub-menu.
If sent while a data display is on screen, moves the
display to the right. No operation is performed if sent
during recording.
Starts fast-forwarding.
If sent during playback, starts fast-forward playback.
If sent during still mode, advances the image by one
frame (field).
SHIFT +/
(65H)
If sent while a menu screen is displayed, selects the
setting item, changes the setting, or changes
(increases) the set value.
SHIFT -/
(66H)
If sent while a menu screen is displayed, selects the
setting item, changes the setting, or changes
(decreases) the set value.
OSD/EXIT (8EH)
If sent while the main menu or a sub-menu is
displayed, exits menu settings.
If sent during recording or playback, changes/hides
the operation display position.
MENU RESET (E1H)
If a menu screen is displayed, resets (initializes) that
menu's settings.
Commands for acquiring information
When a command for acquiring information is sent, the
recorder returns the information (data) for the command.
STATUS SENSE (D7H)
Returns the recorder's operating status in 5 bytes.
( P. 85)
RXD
D7
TXD
Return codes
ACK (0AH)
Returned when the recorder received a valid
command.
RXD
TXD
NAK (0BH)
Returned when the recorder received an undefined
(or non-functional) command.
RXD
TXD
T/D SEARCH (B5H) for RS-232C only
Enter year, month, date, hour, minute, then run T/D
SEARCH with (40H).