Setting Normal Recording Area Overwrite And Remaining Disk Warning On The Operating Display Section - Sanyo DSR-3000 Instruction Manual

Hide thumbs Also See for DSR-3000:
Table of Contents

Advertisement

Available languages

Available languages

RECORDING CONDITIONS SET SETTING
Setting NORMAL RECORDING AREA
OVERWRITE and REMAINING DISK
WARNING on the operating display
section
When the recording areas of the hard disk become full, you can set
whether old images are to overwritten, or whether recording should
stop. If recording is set to stop, the current percentage of free space
remaining on the hard disk will appear on the operating display
section. You can use [REMAINING DISK WARNING] to specify the
amount of free space remaining.
1
When the cursor is at the OVERWRITE setting, turn the
shuttle dial clockwise.
"ON" flashes.
2
Use the jog dial to select the setting (example: OFF), and
then turn the shuttle dial clockwise.
REMAINING DISK WARNING changes from ** to 1%.
Display examples:
OFF: When the normal recording area becomes full, recording
stops.
ON: When the normal recording area becomes full, images are
overwritten automatically starting from the earliest
recorded images.
Note: If "OFF" is selected, the REMAINING DISK WARNING setting
shows the percentage of hard disk space remaining that triggers
the FULL or ALARM FULL indicator to start flashing.
3
Follow the same procedure to make the setting (OFF) for the
ALARM RECORDING AREA.
Note: Make the settings separately for each item in the menu, even if
making a digital connection. The OVERWRITE settings for
second and subsequent units must match the setting for the first
unit.
<RECORDING CONDITIONS SET>
DIGITAL SERIES RECORDING : OFF
TOTAL NUMBER
: **
RECORDING NUMBER
: **
NORMAL RECORDING AREA
OVERWRITE
: ON
ALARM RECORDING AREA
OVERWRITE
: ON
REMAINING DISK WARNING
: **
<RECORDING CONDITIONS SET>
DIGITAL SERIES RECORDING : OFF
TOTAL NUMBER
: **
RECORDING NUMBER
: **
NORMAL RECORDING AREA
OVERWRITE
: OFF
ALARM RECORDING AREA
OVERWRITE
: ON
REMAINING DISK WARNING
: 1%
48
4
When the cursor is at the REMAINING DISK WARNING
setting, turn the shuttle dial clockwise, and then use the jog
dial to set the display value for the amount of disk space
remaining (example: " 5" ).
Note: The REMAINING DISK WARNING setting can be between 1%
(default setting) and 10%.
2
1
5
Press the EXIT/OSD button.
The display returns to the normal screen.
When the remaining disk space in each area reaches 5%, it is
displayed in the operating display section. The FULL (for normal
recording area) or ALARM FULL (for alarm recording area)
indicator on the front of the digital video recorder flashes.
EXIT/OSD
POWER
FULL
01-01-01
00:00:00 EN 0.10SEC
Relationship between RECORDING AREA SET
FULL
and OVERWRITE
<RECORDING AREA SET>
TOTAL CAPACITY
: 80GB
NORMAL RECORDING AREA
: 80 %
AREA FULL RESET
->
ALARM RECORDING AREA
: 19 %
AREA FULL RESET
->
ARCHIVE AREA
:
1 %
AREA FULL RESET
->
CAUTION : WHEN THE AREA SETTING IS CHANGED.
THE WHOLE AREA WILL BE INITIALIZED !
If the normal recording area and alarm recording area become full,
select AREA FULL RESET for the normal recording area or alarm
recording area in the RECORDING AREA SET menu. (See page 46.)
Note: No audio input is provided from the digital video input terminals.
Audio signals can be input as analog signals via the audio input
terminals (such as the MIC terminal). For details on
CONNECTIONS, see page 8.
<RECORDING CONDITIONS SET>
DIGITAL SERIES RECORDING : OFF
TOTAL NUMBER
: **
RECORDING NUMBER
: **
NORMAL RECORDING AREA
OVERWRITE
: OFF
ALARM RECORDING AREA
OVERWRITE
: OFF
REMAINING DISK WARNING
: 5%
FULL
ALARM FULL
FULL
ALARM FULL
FULL
FULL
ALARM FULL
ALARM FULL
ALARM FULL
LOCK
5%
ALARM FULL
ALARM FULL
<RECORDING CONDITIONS SET>
DIGITAL SERIES RECORDING : OFF
TOTAL NUMBER
: **
RECORDING NUMBER
: **
NORMAL RECORDING AREA
OVERWRITE
: ON
ALARM RECORDING AREA
OVERWRITE
: ON
REMAINING DISK WARNING
: **