Requirements Table - ABB ACS800-U7 Hardware Manual

Acs800 45 to 560 kw; 50 to 600 hp
Hide thumbs Also See for ACS800-U7:
Table of Contents

Advertisement

40

Requirements table

The following table shows how to select the motor insulation system and when an
optional drive du/dt and common mode filters and insulated N-end (non-drive end)
motor bearings are required. Ignoring the requirements or improper installation may
shorten motor life or damage the motor bearings and voids the warranty.
Motor
type
ABB motors
Random-
wound
M2_,
M3_ and
M4_
Form-
wound
HX_ and
AM_
Old*
form-
wound
HX_ and
modular
Random-
wound
HX_ and
AM_ **
HDP
*
manufactured before 1.1.1998
**
For motors manufactured before 1.1.1998, check for additional instructions with the motor
manufacturer.
Planning the electrical installation
Nominal AC supply
voltage
Motor insulation
U
< 500 V
Standard
N
500 V < U
< 600 V
Standard
N
or
Reinforced
600 V < U
< 690 V
Reinforced
N
(cable length <
150 m)
600 V < U
< 690 V
Reinforced
N
(cable length >
150 m)
380 V < U
< 690 V
Standard
N
380 V < U
< 690 V
Check with the
N
motor
manufacturer.
0 V < U
< 500 V
Enamelled wire
N
with fiber glass
500 V < U
< 690 V
N
taping
Consult the motor manufacturer.
Requirement for
ABB du/dt and common mode filters, insulated
system
P
< 100 kW
N
and
frame size <
IEC 315
P
< 134 hp
N
and
frame size <
NEMA 500
-
+ du/dt
-
+ du/dt
-
n.a.
+ du/dt with voltages over 500 V + N + CMF
+ N + CMF
+ du/dt + N + CMF
N-end motor bearings
100 kW < P
< 350 kW
N
or
IEC 315 < frame size <
IEC 400
134 hp < P
N
or
NEMA 500 < frame size <
NEMA 580
+ N
+ du/dt + N
+ N
+ du/dt + N
+ N
+ N + CMF
< 469 hp

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acs800-07

Table of Contents