Type designation key

The type designation key contains information on the specifications and
configuration of the drive. The first digits from left express the basic configuration
(eg, ACS800-07-0170-5). The optional selections are given thereafter, separated by
+ signs (eg, +E202). The main selections are described below. Not all selections are
available for all types. For more information, refer to ACS800 Ordering Information
(EN code: 64556568, available on request).
Selection
Product series
Type
Size
Voltage range
(nominal rating in bold)
Optional selections
Degree of protection
Construction
Resistor braking
Filter
Line options
Alternatives
ACS800 product series
07
cabinet built. When no options are selected: IP21 (UL type1),
main switch fuse with aR fuses, 230 VAC control voltage, control
panel CDP312R, no EMC filter, standard software, bottom entry
and exit of cables, cable lead through entry, boards without
coating, one set of default language documents.
U7
cabinet built (USA). When no options are selected: UL type1
(IP21), US type main switch fuse, 115VAC control voltage, control
panel CDP312R, no EMC filter, standard software (US), top entry
and exit of cables, cable conduit entry, common mode filter in R8,
one set of default language documents.
See
Technical
data:
IEC data
3
380/400/415 VAC
5
380/400/415/440/460/480/500 VAC
7
525/575/600/690 VAC
Eg, ACS800-07-0170-5+E202
+B053
IP22 (UL type 1)
+B054
IP42 (UL type 2)
+B055
IP54 (UL type 12)
+B059
IP54R with connection to air outlet duct
+C121
marine construction (reinforced mechanics and fastening,
marking of conductors according to class A1, door handles, self-
extinctive materials)
+C129
UL listed (for ACS800-07 units only): US type main switch fuse,
115 VAC control voltage, US cable conduit entry, all components
UL listed/recognized, max. supply voltage 600 V.
+C134
CSA marked. US/CSA type main switch fuse, bottom entry and
exit, 115 VAC control voltage, all components UL/CSA listed/
recognized, max. supply voltage 600 V.
+D150
brake chopper (external resistor)
+D151
brake resistor
+E200
EMC/RFI filter for second environment TN (grounded) system
+E202
EMC/RFI filter for first environment TN (grounded) system,
restricted (A limits)
+E210
EMC/RFI filter for second environment TN/IT (grounded/
ungrounded) system
+E205
du/dt filter
+E206
sine filter
+E208
common mode filter
+F250
line contactor
+F251
gG line fuses