Capacitors; Reforming; Replacing The Capacitor Pack (R7) - ABB ACS800-U7 Hardware Manual

Acs800 45 to 560 kw; 50 to 600 hp
Hide thumbs Also See for ACS800-U7:
Table of Contents

Advertisement

104
10
9
8
8
9
8
8

Capacitors

The drive intermediate circuit employs several electrolytic capacitors. Their lifespan
depends on the operating time of the drive, loading and ambient temperature.
Capacitor life can be prolonged by lowering the ambient temperature.
It is not possible to predict a capacitor failure. Capacitor failure is usually followed by
damage to the unit and an input cable fuse failure, or a fault trip. Contact ABB if
capacitor failure is suspected. Replacements are available from ABB. Do not use
other than ABB specified spare parts.

Reforming

Reform (re-age) spare part capacitors once a year according to ACS 600/800
Capacitor Reforming Guide [code: 64059629 (English)].

Replacing the capacitor pack (R7)

Replace the capacitor pack as described in section
(R7)
Maintenance
on page 96.
11
11
12
Replacing the drive module fan

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acs800-07

Table of Contents