Installing/mounting
4.3 Transmitter installation
Direct sunlight
Device damage.
The device can overheat or materials become brittle due to UV exposure.
• Protect the device from direct sunlight.
• Make sure that the maximum permissible ambient temperature is not exceeded. Refer
4.3.1

Wall mounting

1. Prepare holes with aid of mounting bracket, see Mounting bracket (Page 230).
2. Fasten mounting bracket with black cushion pad to wall (torque 10 Nm).
4.3.2

Pipe mounting

1. Mount mounting bracket with cushion pad on pipe using fastening brackets/U-bolts and
supplied pipe adaptor. Note: U-bolts and other miscellaneous hardware are not supplied
with the flowmeter.
2. Tighten nuts (torque: 10 Nm).
Note
Hygienic applications
If the device is wall or pipe-mounted in a hygienic application, always use domed nuts.
42
CAUTION
to the information in Chapter "Technical data (Page 196)".
Operating Instructions, 05/2015, A5E03361511-AF