Mitsubishi Electric MELSEC iQ-R Series User Manual page 63

Melsec iq-r cc-link system master/local module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Item
Description
Model Name
The module model name is displayed. If the module information cannot be
found, "Module with No Profile Found" is displayed.
Station Type
Select the station type. Set the same type of the slave station actually
connected.
Version
Set CC-Link version of the slave station.
Select the mode of the master/local module if the slave station is a master/local
module.
Select the same CC-Link version as the version of the slave station actually
connected. If not, data link cannot be performed.
# of STA Occupied
Set the number of occupied stations of the slave station. Set it to increase the
number of link points per slave station.
Expanded Cyclic Setting
Set the extended cyclic setting for the slave station. Set it to increase the
number of link points per slave station.
Set it only when the mode of the slave station is remote net Ver.2 mode.
Remote Station Points
Set the number of points of remote I/O (RX, RY) occupied by the slave station.
Set it to save the devices of the CPU module that are set for the link refresh
targets.
Set it only when the mode of the master station is remote net Ver.2 mode, or
when the mode of the master station is remote device net Ver.2 mode and the
slave station is the remote I/O station.
Reserved/Err Invalid STA
Set it to reserve the slave station or to set the slave station as an error invalid
station.
• For slave stations that will be connected in future, set them as reserved
stations.
• To prevent slave stations from being detected as faulty stations at the data
link error, set them as error invalid stations.
• When the master station is remote net Ver.2 mode or remote device net Ver.2
mode, the number of points of a reserved station can be set to zero. Set zero
points for a reserved station using the engineering tool.
• When a slave station that has been set as an error invalid station is specified
as a reserved station, reserved station selection is prioritized.
• If an error has occurred in all the slave stations set as an error invalid station,
the ERR. LED turns on.
Intelligent Buffer Selection
Set the size of buffer memory used to perform transient transmission with
(word)
dedicated instructions. This item can be set only when a slave station is a local
station, intelligent device station, or standby master station.
■Send
Set the size of send buffer to send data using the RIWT instruction. This item
must be set when modules on the standby master station are not MELSEC iQ-
R series modules.
■Receive
Set the size of receive buffer to receive data using the RIRD instruction. This
item must be set when modules on the standby master station are not MELSEC
iQ-R series modules.
■Auto
Set the size of automatic update buffer to communicate with an intelligent
device station using automatic update buffer. Set the size required for each
intelligent device station.
Station-specific mode setting
Set the station-specific mode for the slave station. This item can be set only
when the slave station supports the station-specific mode.
Properties
Right-click the module in "Network map" and select "Properties".
The model name or manufacturer is displayed.
Setting range
The setting varies depending on the set
module.
The setting varies depending on the set
module.
The setting varies depending on the set
module.
The setting varies depending on the set
module.
The setting varies depending on the set
module.
• No Setting
• Reserved Station
• Error Invalid Station
(Default: No Setting)
Send: 0, 64 to 4096
Note that the total buffer size of "Send" and
"Receive" for all slave stations must be
4096 or less.
(Default: 64)
Receive: 0, 64 to 4096
Note that the total buffer size of "Send" and
"Receive" for all slave stations must be
4096 or less.
(Default: 64)
Auto: 0, 128 to 4096
Note that the total buffer size of "Auto" for all
slave stations must be 4096 or less.
(Default: 128)
The setting varies depending on the set
module.
The setting varies depending on the set
module.
2 PARAMETER SETTINGS
2.3 Basic Settings
2
61