For users operating robots that have not been mounted with an operation panel:
Operation of robot programs such as start-up and shutdown are carried out using external signals
(exclusive input/output signals). This instruction manual is based on robots that are mounted with an
operation panel at the front of the controller, and these operations are explained using key opera-
tions on that panel. Using the parameter settings, please assign exclusive input/output signals that
correspond with each key operation to general purpose input/output signals, and operate the robot
using signal operations.
The following table details exclusive input/output signals that correspond with the key operations of
the operation panel explained in this manual. Please use this as a reference to assign signals and
operate the robot.
For further details regarding parameters please see the separate instruction manual "Detailed expla-
nations of functions and operations".
Table: Conversion table of the buttons and dedicated I/O signals
Operation panel
button, lamp
START button
START
START button lamp
STOP button
STOP
STOP
button lamp
RESET
ERRRESET
button
RESET
button lamp
SLOTINIT
CHNG DISP
PRGSEL
button
UP/DOWN
button
PRGOUT
OVRDSEL
OVRDOUT
LINEOUT
ERROUT
IODATA
END
CYCLE
button
END
button lamp
SVO.ON
SRVON
button
SVO.ON
button lamp
SVO.OFF
SRVOFF
button
SVO.OFF
button lamp
Parameter
Class
name
Input
Starts a program.
Output
Indicates that a program is being executed.
Input
Stops a program.
Output
Indicates that the program is paused.
Input
Releases the error state.
Output
Indicates that an error has occurred.
Input
Cancels the paused status of the program and brings the exe-
cuting line to the top. Executing a program reset makes it possi-
ble to select a program.
Output
Outputs that in the program selection enabled state.
Input
Selects the value inputted into the signal assigned to the numer-
ical input as a program number.
Output
-
Input
Outputs the program number selected to the signal assigned to
the numerical output.
Output
Indicates outputting the program number to the numerical out-
put.
Input
Sets the value inputted into the signal assigned to the numerical
input as a override.
Output
-
Input
Outputs the override value to the signal assigned to the numeri-
cal output.
Output
Indicates outputting the override value to the numerical output.
Input
Outputs the current line number to the signal assigned to the
numerical output.
Output
Indicates outputting the current line number to the numerical
output.
Input
Outputs the error number to the signal assigned to the numerical
output.
Output
Indicates outputting the error number to the numerical output.
Input
Reads the program number and the override value as a binary
value.
Output
Outputs the program number, line number and override value as
a binary value.
Input
Starts the cycle stop.
Output
Outputs that the cycle stop is operating.
Input
Turns ON the servo power supply.
Output
Indicates the servo power supply is ON.
Input
Turns OFF the servo power supply.
Output
This output indicates a status where the servo power supply
cannot be turned ON. (Echo back)
Function
Default
setting
3,0
0,-1
2,2
-1,-1
-1,
-1,-1
-1,
-1,-1
-1,-1
-1,-1
-1,-1,
-1,-1
-1,-1
4,1
1,-1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cr751-qCr760-dCr750-qCr751-d

Table of Contents