ABB SM2000 User Manual page 80

Advanced videographic recorder
Hide thumbs Also See for SM2000:
Table of Contents

Advertisement

Advanced Videographic Recorder
SM2000
100
Sample Interval
Maximum Value over sample interval
Instantaneous Value at time of sample
Average Value over sample interval
Raw
Input
Value
Minimum Value over sample interval
0
12:00:01
12:00:00
(Current
(Previous
Sample)
Sample)
•1 If this parameter is changed, internally recorded data files are recreated and unarchived data is lost.
78
t
Select the filter to be applied to the electrical input prior to
•1
sampling.
Notes.
Applicable to analog sources only.
Filters are applied to the recorded values shown on the
chart view only, not to instantaneous values displayed on
the channel indicators or bargraphs.
Instantaneous – A single value based on process conditions
at the time of sampling.
Average
– The average value of the analog signal since
the previous sample.
Minimum
– The minimum value of the analog signal
since the previous sample.
Maximum
– The maximum value of the analog signal
since the previous sample.
Max & min
– Two values are recorded to capture the
maximum & minimum signal values since the
previous sample. This allows the memory
use to be extended by permitting a slower
sample rate to be selected without losing the
transient behavior of the signal.
Select a signal source to enable/disable recording of the
A
channel data. Refer to Appendix A, page 108 for a description
of the available sources.
Note. This signal is edge-triggered. A rising edge (inactive to
active) enables recording. A falling edge (active to inactive)
disables recording.
Enabled
Disabled
4 CONFIGURATION
IM/SM2000
Issue 11

Advertisement

Table of Contents
loading