Raid Super Capacitor Module Replacement - Lenovo thinksystem SR630 Maintenance Manual

Hide thumbs Also See for thinksystem SR630:
Table of Contents

Advertisement

Figure 97. Instruction for sliding the retainer
Step 4.
Align the blue plastic supports at each end of the M.2 backplane with the guide pins on the system
board. Then, insert the M.2 backplane into the M.2 slot on the system board and press it down to
fully seat it.
Figure 98. M.2 backplane installation
After installing the M.2 drive and M.2 backplane:
1. Reinstall the riser assembly next to the M.2 backplane. See "Install a riser card" on page 72.
2. Complete the parts replacement. See "Complete the parts replacement" on page 141.

RAID super capacitor module replacement

Use this information to remove and install a RAID super capacitor module.
104