3.1 ENERVISTA 650 SETUP SOFTWARE

3.1.7.1 Product setup menu

Product Setup
Communication
Settings
ModBus User Map
Fault Report
Oscillography
Data Logger
Demand
Time Settings
(*) indicates online only, (**) indicates offline only

3.1.7.2 Communication settings menu

This section details the settings related to communication parameters for the different protocols available in the F650.
COMMUNICATIoN
SETTINGS
Serial Ports
Network (Ethernet)
ModBus Protocol
DNP3 Slave
IEC 870-5-104
SNTP (*)
PROCOME
PTP 1588
Routing
(*) indicates online only, (**) indicates offline only
3-18
Serial Ports, Network (Ethernet), ModBus Protocol, DNP Slave, IEC 870-5-104, SNTP settings
and procome (if available on model selection), PTP1588 and Routing (for firmware version
7.00 and higher)
ModBus user map definition. The ModBus user map is formed by 256 records, selectable
from the complete relay ModBus map.
Fault report settings. Possibility to show fault reports on HMI screen.
Oscillography settings (trigger position, samples per cycle, etc.). The trigger and digital
channels (up to 16) must be configured in Setpoint > Relay configuration.
Data logger configuration
Demand settings. The demand trigger and demand reset signals must be configured in
Setpoint > Relay configuration
Time settings.
Baud rate and parity for COM1 and COM2 serial communication ports.
Ethernet communication parameters for ETH_1/ETH2 or ETH_E/ETH_A/ETH_B
(Depending on model) (IP Address, Netmask, Gateway IP)
NOTE: The ModBus Slave address used by Ethernet ports is the one set for
COM2.EnerVista 650 Setup software allows programming two different Ethernet
addresses, but the first IP has always to be set as the second IP Address is an Alias.
ModBus Slave Addresses for serial and Ethernet communication and the ModBus port
number used for ModBus TCP/IP
Physical port, Slave Address for DNP, IP Addresses for Masters, TCP/UDP Port,
Unsolicited Response parameters, Analog scale factors and deadbands, message
fragment size, Binary input block.Available for standard and IEC61850 models.
TCP Port, Common Addr of ASDU, Cyclic Meter Period and, Synchronization Event
settings.Available for standard and IEC61850 models.
Synchronization over Ethernet settings
Comm port and slave number for procome protocol. Only available for
procome models (5).
Precission Time Protocol 1588 settings. (Available on fw version 7.00 or higher)
A default route and a maximum number of 6 static routes may be configured. The
default route is used as the last choice, if no other route towards a given destination is
found.This option is only available for version 7.00 and higher.
F650 DIGITAL BAY CONTROLLER
CHAPTER 3: INTERFACES, SETTINGS & ACTUAL VALUES