Siemens SINUMERIK 810D Configuration Manual page 91

Hide thumbs Also See for SINUMERIK 810D:
Table of Contents

Advertisement

I/O Modules
6.1
Single I/O module
Brief description
The single I/O module has 64 inputs and 32 short-circuit-proof outputs
(isolated). Each output has a load rating of 0.5A. The simultaneity factor is 75%.
Up to three single I/O modules can be connected to the SINUMERIK 810D.
Combinations with SIMATIC S7-300 phases are permissible.
Connection
The compact I/O module (connector X3 IN) is connected to the SINUMERIK
to the 810D
810D (connector X111). The max. cable length is 10m. Two different cable
versions are available for connecting one single I/O module to the next:
S
S
6ES7 368-3jjj0-0AA0
X111
810D
6ES7 368-3jjj0-0AA0
X3 IN
6ES7 368-3jjj0-0AA0
X3 OUT
6FC5 411-0AA80-0AA0, length 150mm
Ribbon cable
X404
32 I
Ribbon cable
X405
32 I
Ribbon cable
X402
32O
Fig. 6-1
Connection overview of single I/O module on the 810D
E Siemens AG, 2002. All rights reserved
SINUMERIK 810D Manual Hardware Configuration (PHC) - - 11.02 Edition
For installation of one module: 6ES7 368-3jjj0-0AA0
For single-tier installation of several single I/O modules:
6FC5 411-0AA80-0AA0, length 150mm.
Connecting cable shielded for single-tier configuration only
6FC5 411-0AA80-0AA0, length 150mm
IN
OUT
IN
OUT
X3
X3
IN OUT
X3
SINUMERIK 810D
IM 361 or second single I/O module
Terminal strip converter
Terminal strip converter
Terminal strip converter
6
6-89

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 810deSinumerik 810d powerlineSinumerik 810de powerline

Table of Contents