8 DMP Compact Modules
8.1 DMP compact module 16I (6FC5 111-0CA01-0AA0)
Table 8-1
Number of inputs
Floating
Supply voltage V
Input voltage (rated value)
Input voltage
Input current for "1" signal
Delay time
Delay time
Cable length
Weight
Degree of protection according to DIN 40050
Humidity rating according to DIN 40040
8-104
Technical data DMP compact module 16I
LOAD
- Rated value
- Permissible range
- Ripple
- For "0" signal
- For "1" signal
for tp
LH
for tp
HL
SINUMERIK 810D Manual Hardware Configuration (PHC) - - 11.02 Edition
16 digital inputs
Yes
24VDC
20.4V to 28.8V
3.6Vpp
24VDC
- -3 to +5V
+13V to +33V
+ 2mA to + 5mA
tp
= type 1msec
LH
tp
= type 1msec
HL
max. 30m
approx. 125g
IP20
F
E Siemens AG, 2002. All rights reserved