03.02
12.95
Attaching the
The shield plate is attached to the bottom of the 3-axis CCU box by means of
shield plate
three screws; for the 2-axis CCU box, see the shield plate installation diagram).
The shield plate is included in the box. The tube clip for shield connection is
included in the scope of supply for the preassembled SIEMENS motor
connecting lead.
130
Ventilation
space
100mm
Fig. 3-4
Dimension drawing of the 3
E Siemens AG, 2002. All rights reserved
SINUMERIK 810D Manual Hardware Configuration (PHC) - - 11.02 Edition
Ventilation gap 100mm
During module
installation, keep to
the tightening torque !!
M3 : 0.8Nm
M4 : 1.8Nm
M5 : 3Nm
M6 : 6Nm
Motor connection
A3
A2
A1
288
Shield plate
-
axis CCU box
3 Design and Installation of the 810D
3.2 Installing the SINUMERIK 810D
Additional connection option
for M5x10 shield connection
25
100
150
Equipotential bonding connection