12.95
Typical
circuits
Fig. 8-7
Table 8-6
Number of inputs
Floating
Supply voltage V
Input ranges (rated value)
Power consumption (24V)
Sensor connection
Digital representation of input signal
Total error over temperature range 0 to 55_C including resi-
dual deflection
Cable length (shielded)
Weight
Degree of protection according to DIN 40050
Humidity rating according to DIN 40040
The DMP compact module 1I NC analog is used for input and digitizing of an
analog voltage value. This voltage value is measured by a floating differential
input.
Analog value
The result from the converter is available to the user as a two's complement.
representation
The resolution is 4.88mV for one bit. The duration of a converter cycle (from
initiating the conversion until the moment the result can be read) is max.
75μsecs.
E Siemens AG, 2002. All rights reserved
SINUMERIK 810D Manual Hardware Configuration (PHC) - - 11.02 Edition
8.5 DMP compact module 1I NC analog (6FC5 211-0AA10-0AA0)
Analog voltage measurement
X2
S
M
- -
+
M
S
6
5
4
3 2
1
Difference input
(common-mode
V
interferences
are suppressed)
Typical circuits for the DMP compact module 1I NC analog
Technical data DMP compact module 1I NC analog
- Rated value
LOAD
- Permissible range
- Ripple
8 DMP Compact Modules
X2
S
M
- -
+
M
S
6
5
4
3 2
1
Unipolar
V
(standard)
1 analog input
Yes
24VDC
20.4V to 28.8V
3.6Vpp
10V
85mA
See below
11 bits + sign
0.6%
max.
30m
approx. 160g
IP20
F
8-113