3.1 ENERVISTA 650 SETUP SOFTWARE INTERFACE 3 HUMAN INTERFACES. SETTINGS & ACTUAL VALUES
Table 3.5: GENERAL OVERVIEW OF SETPOINT MENU IN ENERVISTA 650 SETUP:
SETPOINT
3
Options enabled only in On-line mode are marked as (*). Options enabled only in Off-line mode are marked as (**)
3.1.8.1 PRODUCT SETUP
Table 3.6: GENERAL OVERVIEW OF PRODUCT SETUP MENU:
PRODUCT
SETUP
Options enabled only in On-line mode are marked as (*). Options enabled only in Off-line mode are marked as (**)
3-20
Communications settings for all protocols and physical mediums.
Product Setup
ModBus user map definition, fault report, oscillography, data logger
demand settings and Time Settings.
General Settings, Flex Curves Definition, Breaker settings maintenance,
System Setup
switchgear snapshot events management and Miscellaneous Settings.
Phase, Neutral, Ground, Sensitive Ground and Negative Sequence
Protection Elements
Current Settings. Voltage Elements settings and Power Settings
management.
Setting groups, under and overfrequency settings, synchrocheck,
autoreclose, breaker failure, VT fuse failure, broken conductor, locked
Control Elements
rotor settings management, Pulse Counters, Analog comparators,
Frequency Rate of Change, Load encroachment, max number of starts,
Digital Counters, Cold Load Pickup and PLC Timer Masks
Contact I/O settings for all boards available in device, Remote Comms
Inputs/Outputs
Force Outputs and Virtual inputs.
Menu that encompass the most important settings to configure the
Quick Settings
device such as; Current and Voltage sensing or current protection
element.
Configuration of Outputs, LEDs, Operations, Protection Elements,
Oscillography, Control Events, Control Elements, Switchgear, Inputs,
Relay Configuration
Virtual Inputs, Operations and HMI. Whole relay configuration with
internal relay signals or user-definable ones as logic (virtual outputs).
Logic configuration graphic editor (PLC Editor). It is a PLC Project file
editor that contains all the internal drawings used to make the logic
Logic Configuration
(virtual outputs) based on IEC 61131-3 standard. Functional block
diagram (FDB).
Procome Configuration tool. Only available for Procome models (5)
Procome Configuration
when communicating through Ethernet with EnerVista 650 Setup
IEC103 settings for available IEC103 models (3) when communicating
IEC103 Configuration
through Ethernet with Enervista 650 Setup
Relay synchronization to computer clock or to user-definable date and
Clock (*)
time. On-line mode only.
Serial Ports, Network (Ethernet), ModBus Protocol, DNP Slave, IEC 870-
Communication
5-104, SNTP settings and procome (if available on model selection),
Settings
PTP1588 and Routing (for firmware version 7.00 and higher)
ModBus user map definition. The ModBus user map is formed by 256
ModBus User Map
records, selectable from the complete relay ModBus map.
Fault Report
Fault report settings. Possibility to show fault reports on HMI screen.
Oscillography settings (trigger position, samples per cycle, etc.). The
Oscillography
trigger and digital channels (up to 16) must be configured in
"Setpoint>Relay configuration".
Data Logger
Data logger configuration
Demand settings. The demand trigger and demand reset signals must be
Demand
configured in "Setpoint>Relay configuration"
Time Settings
Time settings.
F650 Digital Bay Controller

3.1.8 SETPOINT MENU OVERVIEW

GEK-106310AE