System Controls - ABB ACS150 User Manual

Table of Contents

Advertisement

Index Name/Selection
8 = SUPRV 1 OVER
9 = SUPRV 1 UNDER See selection SUPRV 1 OVER.
10 = SUPRV 2 OVER
11 = SUPRV 2 UNDER See selection SUPRV 2 OVER.
12 = SUPRV 3 OVER
13 = SUPRV 3
UNDER
14 = AT SET POINT
15 = FAULT(RST)
16 = FLT/ALARM
17 = EXT CTRL
18 = REF 2 SEL
19 = CONST FREQ
20 = REF LOSS
21 = OVERCURRENT Alarm/Fault by overcurrent protection function
22 = OVERVOLTAGE
23 = DRIVE TEMP
24 =
UNDERVOLTAGE
25 = AI1 LOSS
27 = MOTOR TEMP
28 = STALL
29 = UNDERLOAD
33 = FLUX READY
1404
RO1 ON DELAY
0.0...3600.0 s
1405
RO1 OFF DELAY
0.0...3600.0 s
16 SYSTEM
CONTROLS
1601
RUN ENABLE
0 = NOT SEL
1 = DI1
Description
Status according to supervision parameters 3201...3203.
Status according to supervision parameters 3204...3206.
Status according to supervision parameters 3207...3209.
See selection SUPRV 3 OVER.
Output frequency is equal to the reference frequency.
Fault. Automatic reset after the autoreset delay. See parameter group
31 AUTOMATIC
RESET.
Fault or alarm
Drive is under external control.
External reference REF2 is in use.
A constant speed is in use. See parameter group
Reference or active control location is lost.
Alarm/Fault by overvoltage protection function
Alarm/Fault by drive overtemperature protection function
Alarm/Fault by undervoltage protection function
Analog input AI1 signal is lost.
Alarm/Fault by motor overtemperature protection function. See parameter
3005
MOT THERM PROT.
Alarm/Fault by stall protection function. See parameter
FUNCTION.
Alarm/Fault by underload protection function. See parameter
UNDERLOAD FUNC.
Motor is magnetised and able to supply nominal torque.
Defines the operation delay for relay output RO.
Delay time. The figure below illustrates the operation (on) and release (off)
delays for relay output RO.
Control event
Relay status
Defines the release delay for relay output RO.
Delay time. See the figure for parameter
Run Enable, parameter lock etc.
Selects a source for the external Run Enable signal.
Allows the drive to start without an external Run Enable signal.
External signal required through digital input DI1. 1 = Run Enable. If Run
Enable signal is switched off, the drive will not start or coasts to stop if it is
running.
12 CONSTANT
1404 ON DELAY 1405 OFF DELAY
1404
RO1 ON DELAY.
SPEEDS.
3010
STALL
3013
0
0
0 = NOT SEL
Actual signals and parameters
77