Index Name/Selection
3105
AR OVERVOLTAGE
0 = DISABLE
1 = ENABLE
3106
AR UNDERVOLTAGE Activates/deactivates the automatic reset for the intermediate link
0 = DISABLE
1 = ENABLE
3107
AR AI<MIN
0 = DISABLE
1 = ENABLE
3108
AR EXTERNAL FLT
0 = DISABLE
1 = ENABLE
Description
Activates/deactivates the automatic reset for the intermediate link
overvoltage fault. Automatically resets the fault (DC OVERVOLT, code:
F0002) after the delay set by parameter
Inactive
Active
undervoltage fault. Automatically resets the fault (DC UNDERVOLTAGE,
code: F0006) after the delay set by parameter
Inactive
Active
Activates/deactivates the automatic reset for fault AI1 LOSS, code: F0007
(analog input signal under the allowed minimum level). Automatically resets
the fault after the delay set by parameter
Inactive
Active
WARNING! The drive may restart even after a long stop if the
analog input signal is restored. Ensure that the use of this feature
will not cause danger.
Activates/deactivates the automatic reset for the EXTERNAL FAULT 1/2
(code: F0014/0015). Automatically resets the fault after the delay set by
parameter
3103
DELAY TIME.
Inactive
Active
3103
DELAY TIME.
3103
DELAY TIME.
3103
DELAY TIME.
Actual signals and parameters
93
0 = DISABLE
0 = DISABLE
0 = DISABLE
0 = DISABLE