Function
ON/OFF (system)
Operation status of each group
in the system
Filter sign
Monitor
*1
Local operation prohibition
Error
External output
Date and time
License
Unit Info.
Network
Operation
*1
Groups
Blocks
Interlock
Floor Layout
Error history monitor
Monitor
Refrigerant system
*1
configuration confirmation
Maintenance User
Operation
*1
Building Manager
Connection/Interlock
Information
Error history
Data
Schedule data
back-up
Current time
Saving the data on a USB drive
Device
Touch panel cleaning
maintenance
*1: The item and range that can be operated or monitored depend on the function of the indoor unit.
*2: The maximum number of the controllable units varies depending on the indoor unit.
The ON/OFF indicator lamp indicates if one or more groups or all the groups in the
system are stopped.
Operation status (ON/OFF), operation mode, fan speed, temperature setting, air
flow direction, operation status (ON/OFF) of interlocked units, timer enable/disable
status of each group is displayed.
Indicates that the filter on the units in a given group is due for cleaning.
Displays the functions that the controller forbids or the functions that are forbidden
by other controllers.
The address of the unit in error, error code, and the address of the unit that detected
the error will appear.
Outputs signals (run/stop, error) to an external device. Requires an external input/
output adapter (sold separately).
This function is used to set the current date/time and daylight savings time.
This function is used to register license.
This function is used to set unit name, ID number, brightness of the LCD, sound
volume, date format, time format, temperature unit, and display language.
This function is used to set the IP address, subnet mask address, and gateway
settings for the LAN and also to set the address, K-transmission converter address,
local control prohibit settings, and external input settings for the M-NET.
This function is used to register indoor units, LOSSNAY units, remote controllers, and
lower-level system controllers to a group.
This function is used to register a group to a block.
This function is used to interlock the operation of indoor units and LOSSNAY units.
This function is used to make the basic settings for the floor layout and display position
of the groups.
Up to 128 errors can be stored in memory. (64 unit errors, 64 communication errors)
Allows the user to see which indoor units are connected to each outdoor unit.
Allows the maintenance user name and password to be set.
Allows the building manager name, password, function enable/disable settings to be
made.
Group setting information and interlock setting information are retained, even if power
is turned off.
Retained, even if power is turned off.
Schedule information of each group is retained, even if power is turned off.
Current time is retained by the build-in capacitor for a week, even if power is turned off.
The initial setting data, history data, calculated values, and computed values can be
stored to a USB drive.
Touch panel is locked and can be cleaned.