PID Instruction (FNC 88)
Set item
Input variation (incremental)
*1
S
+20
3
alarm set value
Input variation (decremental)
*1
S
+21
3
alarm set value
Output variation
(incremental) alarm set value
*1
S
+22
3
Output upper limit set value
Output variation
(decremental) alarm set value
*1
S
+23
3
Output lower limit set value
*1
Alarm output
S
+24
3
The setting below is required when the limit cycle method is used (when the operation direction (ACT) b6 is set to ON).
PV value threshold
S
+25
3
(hysteresis) width (SH
Output value upper limit
S
+26
3
(ULV)
Output value lower limit
S
+27
3
(LLV)
Wait setting from end of tuning
cycle to start of PID control
S
+28
3
(K
)
W
*1.
+20 to +24 become occupied only if bits 1, 2, or 5 are set to "1" to determine the action (ACT) of
S
3
+1.
S
3
M-8
PLC User's Manual - Analog Control Edition
3UC
0 to 32767
0 to 32767
0 to 32767
−32768 to 32767
0 to 32767
−32768 to 32767
0: Input variation (incremental) is not
exceeded.
bit0
1: Input variation (incremental) is
exceeded.
0: Input variation (decremental) is
not exceeded.
bit1
1: Input variation (decremental) is
exceeded.
0: Output variation (incremental) is
not exceeded.
bit2
1: Output variation (incremental) is
exceeded.
0: Output variation (decremental) is
not exceeded.
bit3
1: Output variation (decremental) is
exceeded.
Set it according to measured value
)
(PV) fluctuation.
PV
Set maximum value (ULV) of output
value (MV).
Set minimum value (LLV) of output
value (MV).
−50 to 32717 %
Setting
It is valid when operation direction
(ACT) (bit 1 of
It is valid when operation direction
(ACT) (bit 1 of
It is valid when operation direction
(ACT) (bit 2 of
or (ACT) (bit 5 of
It is valid when operation direction
(ACT) (bit 2 of
or (ACT) (bit 5 of
It is valid when operation direction
(ACT) (bit 2 of
or (ACT) (bit 5 of
It is valid when operation direction
(ACT) (bit 2 of
or (ACT) (bit 5 of
It is valid when operation direction
(ACT) (bit 1 or bit 2 of
"1".
They are occupied when operation
direction (ACT) (bit 6) is "ON (limit
cycle method)."
3 Parameter
3.1 Parameter List: (S3) to (S3) + 28
Remarks
Reference
S
+1) is "1".
3
S
+1) is "1".
3
S
+1) is "1"
3
S
+1) is "0".
3
Subsection
S
+1) is "0"
3
S
+1) is "1"
3
S
+1) is "1"
3
S
+1) is "0"
3
S
+1) is "0"
3
S
+1) is "1"
3
Subsection
S
+1) is
3
Chapter 4
3.2.2
3.2.8