Mitsubishi Electric FX3G User Manual page 39

Hide thumbs Also See for FX3G:
Table of Contents

Advertisement

FX
/FX
/FX
/FX
/FX
3S
3G
3GC
3U
3UC
Common Items
Type
Voltage/current input/output mixture
FX
-5A
*1
2N
*4 *5
FX
-3A
0N
Temperature sensor input
FX
-8AD
*1
2N
*1
FX
-4AD-TC
2N
FX
-4AD-PT
*1
2N
*1
FX
-4LC
3U
*1. To connect this block to the FX
required.
*2. Refer to the instruction manual of the respective product.
*3. The offset and gain of the FX
indication mode or analog value mV (or
*4. The FX
-3A cannot be connected to the FX
0N
*5. To connect this block to the FX
PLC User's Manual - Analog Control Edition
No. of
Range
channels
Voltage:
-10 V to +10 V DC
Input
4ch
Current:
-20 mA to +20 mA DC
Voltage:
-10 V to +10 V DC
Output
1ch
Current:
0 mA to 20 mA DC
Voltage:
0 V to 10 V DC
Input
2ch
Current:
4 mA to 20 mA DC
Voltage:
0 V to 10 V DC
Output
1ch
Current:
4 mA to 20 mA DC
Type K:
-100 °C to +1200 °C
Type J:
-100 °C to +600 °C
8ch
Type T:
-100 °C to +350 °C
Type K:
-100 °C to +1200 °C
4ch
Type J:
-100 °C to +600 °C
Pt100:
4ch
-100 °C to +600 °C
Example:
Type K:
-100 °C to +1300 °C
4ch
Example:
Pt100:
-200 °C to +600 °C
/FX
3GC
3UC
-5A cannot be adjusted for channels using the analog value direct
2N
Series PLC, either the FX
3UC
Resolution
0.32 mV
(with sign, 16 bits)
Combined use of voltage and
1.25 μA
current is possible.
(with sign, 15 bits)
The offset/gain can be
adjusted.
5 mV
The scaling function is
(with sign, 12 bits)
incorporated.
20 μA
(10 bits)
40 mV
(8 bits)
64 μA
The input format is common to 2
(8 bits)
channels.
The offset/gain can be adjusted.
40 mV
(Common to 2 input channels)
(8 bits)
64 μA
(8 bits)
Combined use of voltage,
current, and thermocouple is
possible.
Compatible with thermocouple
0.1 °C
types K, J, and T.
The unit can be switched between
"Centigrade" and "Fahrenheit."
The sampling function is
incorporated.
Compatible with thermocouple
0.4 °C
types K and J.
The unit can be switched between
0.3 °C
"Centigrade" and "Fahrenheit."
Compatible with the platinum
resistance thermometer sensor
0.2 °C to 0.3 °C
(Pt100 or JPt100).
The unit can be switched between
"Centigrade" and "Fahrenheit."
Compatible with thermocouple
types K, J, R, S, E, T, B, N, PL II,
W5Re/W26Re, U, and L.
Compatible with the platinum
resistance thermometer sensor
(Pt1000, Pt100, and JPt100).
The unit can be switched between
0.1 °C or 1 °C
"Centigrade" and "Fahrenheit."
(Depends on the
Compatible with the micro
sensor input range.)
voltage input.
The temperature adjustment
function (PID operation, etc.) is
incorporated.
The peak disconnection
detection function is
incorporated.
(A CT sensor is needed.)
Series PLC, either the FX
A) specification mode.
μ
/FX
Series PLC.
3G
3GC
-CNV-IF or FX
2NC
2 Description of Analog Products
2.2 List of Analog Product Models
Function
*3
-CNV-IF or FX
-1PS-5V is
3UC
2NC
-1PS-5V is required.
3UC
A-13
A
Refer-
ence
B
*2
C
*2
D
*2
E
*2
F
*2
G
H
*2
I
J