1. Hydraulic filter
3. Lubricate new filter gasket.
4. Assure filter mounting area is clean. Screw filter on
until gasket contacts mounting plate. Then tighten
filter one–half turn.
5. Start engine and let run for about two minutes to
purge air from the system. Stop the engine and
check the hydraulic oil level and for leaks.

Cleaning Hydraulic Strainer

Service Interval: Every 800 hours
1. Position the vehicle on a level surface, stop engine,
engage the parking brake and remove key from
ignition switch.
2. Remove drain plug (Figure 78) from side of reservoir
and let hydraulic fluid flow into drain pan.
3. Note orientation of hydraulic hose and 90 degree
fitting connected to strainer on side of reservoir.
Remove hydraulic hose and 90 degree fitting.
4. Remove strainer and clean by back flushing with a
clean degreaser. Allow to air dry before reinstalling.
Figure 77
2. Gasket
1. Hydraulic strainer
5. Reinstall strainer.
6. Reinstall hydraulic hose and 90 degree fitting to
strainer in same orientation.
7. Reinstall and tighten drain plug.
8. Fill reservoir with approximately 7.5 qt. of Dexron
IIl ATF. Refer to Checking Hydraulic Fluid.

Emergency Box Raising

(without starting engine)
The box can be raised in an emergency by cranking
starter or by jumping hydraulic system.
Starter Method
• Crank starter while holding lift lever in the raise
position. Run starter for 15 seconds then wait 60
seconds before engaging starter again.
• If engine will not crank, the load and box
(attachment) must be removed to service engine or
transaxle.
• Back another vehicle up to the rear of the disabled
vehicle.
Jumping Hydraulic System