Underfloor Heating Controller (Hce80 Or Hcc80) - Honeywell evohome Installation Manual

Hide thumbs Also See for evohome:
Table of Contents

Advertisement

P24
Underfloor Heating Controller (HCE80 or HCC80)
Central
Controller
If you are NOT following
GUIDED CONFIGURATION
follow these steps on your
Central Controller display
once the underfloor heating
controller and sensors have
been fitted:
1. On the Central
Controller press and
hold "Settings"
for 3
seconds
2. Press the green tick
3. Press ADD A ZONE
4. Press the zone you're
adding the controller
to then select
UNDERFLOOR HEATING
5. You need to install
a sensor (HCW82,
HCF82, DTS92) in each
zone controlled by
the underfloor heating
controller and bind it to
the Central Controller.
You need to repeat this
process for every zone that
uses underfloor heating.
!
Make sure the zone you're
adding on the Central
Controller corresponds
to the correct underfloor
heating zone.
Step 3: Power up and bind devices
Power up and bind an Underfloor Heating
Controller (HCE80 or HCC80)
If you want to control the zone temperature with your
Central Controller (the Central Controller needs to be
located in that zone) press YES, otherwise press NO and
bind a sensor – either Digital Room Thermostat (DTS92)
or Room Temperature Sensor (HCW82/HCF82).
To bind the Digital Room
Temperature Sensor (DTS92)
Press and hold the power button for 2
1
seconds to put the unit into standby
Press the up and down arrows together for
2
three seconds – it should say INst
Press the down arrow – it should say COnt
3
Press the up arrow three times – it should say CLr
4
Press the power button once to clear
5
any previous binding data
Press the up arrow – it should say COnt
6
Press the power button once to send the
7
binding signal to the Central Controller
You should receive a SUCCESS message on the
8
Central Controller (if not go back and re-bind)
2
HOlD
3 SEC

Advertisement

Table of Contents
loading

Table of Contents