Installing the CPE Under a Desk
Position the desk so that it is at least 1/2-inch (12.7 millimeters) from the wall to
Step 1
allow space for the Ethernet cable between the wall and the desk. (See
Figure
Step 2
Locate the screw template. The template is used to align the mounting screw holes
and is also used as a guide to make sure the screws are installed into the desktop
with proper clearance.
Note
Position the screw template underneath the desk so that the two side-by-side slots
Step 3
face the front of the desk (See
the rear of the desk after the CPE is installed.
Note
Note
Cisco 575 LRE CPE Hardware Installation Guide
2-6
2-2, and
Figure
2-7.)
The template has adhesive to hold it in place while you drill holes
underneath the desktop. If you will be using the same screw template
to install several CPEs, do not use the adhesive. In this case, hold the
template against the bottom of the desk while you drill the screw holes
and insert the scews.
Do not attach the screw template to the desk yet.
Allow a minimum of three inches (7.6 centimeters) between the rear
of the desk and the screw template so that there is enough room for the
cables to clear the wall. (See
Figure
2-1.) This ensures that the cables will face
Figure
2-1.)
Chapter 2
Installation
Figure
2-1,
78-11469-01