Installation

DVR Internal Modem Default Settings

Testing a Dial-Up Connection in the Field

40
2.
Plug the other connector in a telephone outlet.
Note
Connect the DVR to a telephone line only if a dial-up connection is planned.
Caution
Power down the DVR before connecting hardware to it. See
on page 31.
For Telco communication, a data-grade (fax) telephone line is preferable to a standard line.
Special features, such as call waiting, should not be available on a telephone line used by
a Rapid Eye Hybrid LT DVR.
Note
For dial-up connections, LocalView is not needed to help set up a remote
connection.
You are ready to power-up the camera(s) and the DVR. See
on page 30.
Table 2-3
Default Settings of the Internal DVR Modem
Field name
TELCO Port
Baud
Wait
Prefix
Initialization
Dialing
Using a standard telephone line, dial the number used to reach the DVR modem, to listen
for an answer tone.
Value
Internal or Port 1
115,200
60
AT
Z
D
Powering Up
Powering the Hybrid LT DVR