NEC Univerge SV8100 Features And Specifications Manual page 1457

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
Guide to Feature Programming
The Level 1, Level 2 and Level 3 columns indicate the programs that are assigned when programming
this feature in the order they are most commonly used. These levels are used with PCPro and WebPro
wizards for feature programming.
Level 1 – these are the most commonly assigned programs for this feature.
Level 2 – these are the next most commonly assigned programs for this feature.
Level 3 – these programs are not often assigned and require an expert level working knowledge of
the system to be properly assigned.
Program
Program Name
Number
10-12-01
CD-CP00-US Network Setup – IP
Address
10-20-01
LAN Setup for External
Equipment – TCP Port
10-20-03
LAN Setup for External
Equipment – Keep Alive Time
Station Message Detail Recording
Description/Comments
Assign the IP Address.
Define the TCP port (0~65535)
when communicating to the SMDR
(type 5).
Define the keep alive time for
communicating to external
equipment.
Assigned Data
1
0.0.0.0~
126.255.255.254
128.0.0.1~
191.254.255.254
192.0.0.1~
223.255.255.254
(default =
192.168.0.10)
0~65535
default:
External Device 1 (CTI
Server) = 0
External Device 2
(ACD MIS) = 4000
External Device 5
(SMDR Output) = 0
External Device 6 (DIM
Output) = 0
External Device 11
(O&M Server) = 8010
External Device 12
(Traffic Report Output)
= 0
External Device 13
(Room Data Output for
Hotel Service) = 0
External Device 14
(IP-DECT Directory
Access) = 0
1~255 (seconds)
(default = 30)
Issue 11.0
Level
2
3
2 - 1425

Advertisement

Table of Contents
loading

Table of Contents