Honeywell OMNI 624 Installation And Setup Manual page 55

Fbii security system
Hide thumbs Also See for OMNI 624:
Table of Contents

Advertisement

Q 11, L4 Restore Reporting – Enter the digit for the type of Restore reports to be sent. Program the
actual trouble Restore report code in Submode 2, Question 44, Location 4. Program the actual zone
Restore report code in Submode 2, Question 44, Location 2.
L4
Send AC
Send Low
Entry
Restore
Bat. Restore
0
1
2
3
4
5
6
7
C
D
E
F
QUESTION 12 SYSTEM OPTIONS
This question defines various system-wide options.
Q 12, L1 – Enter the L1 digit for the desired options from the table that follows.
No Bell
Fast
L1
if Dial
Zones
Entry
Delay
5/6
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Send Zone
Restore
Follows Loop
Double-
Balanced
Zones
No Bell if Dial Delay: If selected, bell sounding will not occur
until the dialer is activated (bell is delayed by the same amount of
time as the dial delay setting). See Question 19, Location 4 for
setting the dial delay (15–255 seconds) and Submode 2, Questions
1–24, Location 4 to enable the dial delay for each zone.
Fast Zones 5/6: Sets zones 5 and 6 to fast response (10mS). If set,
these zones must be wired as NC loops (cannot be double-balanced
zones or part of zone doubling).
Double-Balanced Zones: Select if using double-balanced zones.
This option allows hardwired zones to be wired such that a tamper
will be detected on an open or a shorted loop.
Section 6. System Programming
Restore
Send Zone Restore & Restore Follows
Loop: Normally, zone restores are sent at
bell cutoff, when the panel is disarmed,
and when the panel is reset. If you select
Restore Follows Loop, zone Restore
reports will be sent as soon as the zone
restores.
L1
L2
L3
L4
6–17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents