OMNI624 Installation and Setup Guide
QUESTION 15 SOUND OPTIONS
This question defines sounder and bell options. Enter the digits as follows:
Q 15, L1 – Enter the L1 digit from the table below.
L1
Fob/Key
Arm Bell
Entry
Ding
Ding
0
2
3
4
5
6
7
8
A
B
C
D
E
F
Q 15, L2 – Enter the L2 digit from the table below.
L2
Threshold
Threshold
Entry
Sounder
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
6–24
Disarm
Fast
Ding
Ding
CS Test
Invert Bell
Bell
Ringback
Output
Fob/Keyswitch Ding: If selected, arming from an
RF keyfob or a wired keyswitch will cause the
alarm sounder to ding twice; disarming dings once,
provided that arm/disarm bell ding options (see
below) are selected.
Arm Bell Ding: If selected, the alarm sounder will
ding twice upon arming.
Disarm Ding: If selected, the alarm sounder will
ding once upon disarming.
Fast Ding: If selected, the arming dings will be
shorter tones.
Threshold Sounder: Alerts the user to the
end of exit time by sounding 4 rapid beeps
30, 20, 10, and 5 seconds before exit time
expires. When exit time expires, the keypad
will sound an acknowledgement tone.
Threshold Bell: Similar to threshold
sounder option, except the alarm sounder
will sound 1 second at 30, 20, 10, and 5
seconds before the end of exit time.
CS Test Ringback: If selected, keypads
will beep after the central station has
received the system test code.
Inverted Bell Output: If selected, the
alarm sounder output signal is inverted.
This is useful when using self-activating
alarm sounders.
L1
L2
L3
L4

Hide quick links: