Honeywell OMNI 624 Installation And Setup Manual page 71

Fbii security system
Hide thumbs Also See for OMNI 624:
Table of Contents

Advertisement

Q 23, L4 – Pager Enables for Partitions and Follow Me
L4
Enable User
Enable User
Entry
Page Part. 1
Page Part. 2
0
1
2
3
8
9
A
B
QUESTION 24 KEYPAD TAMPER, NO ARM, AND RF JAM
Q 24, L2 – Keypad Tamper
This question controls keypad tamper and the alerts sounded on a keypad tamper condition.
Keypad
Keypad
L2
Tamper
Tamper
Entry
Enable
Sounder
0
1
3
5
NOTE: Keypad tamper is only available on some OMNI-LCD, OMNI-LCD-US, OMNI-KP, and OMNI-
KP-US keypads. Refer to your keypad instructions to see if your keypad has keypad tamper detection
capabilities.
Q 24, L3 – No Arm if Jam, Supervision, or AC
This question controls arming while in a jam, supervision, or no AC condition.
L3
No Arm
No Arm
Entry
if RF Jam
if Super
0
1
3
5
7
Enable #58
Enable User Page Part. 1–2: If selected, the open
Follow Me
and/or close events selected in L1–L2 above will be
reported to a pager for users in a particular partition.
This setting can be toggled by using the #8 command.
Enable #58 Follow Me: If selected, enables the #58
Quick Command. The #58 Quick command is used to
modify the pager telephone number from the keypad.
Keypad
Keypad Tamper Enable: If enabled, the system will monitor
Tamper
the keypads for a keypad tamper report. If a keypad tamper is
Bell
reported by a keypad, a report will be sent to the central station
if enabled in Submode 2, Question 43, Locations 3 and 4.
Keypad Tamper Sounder: If enabled, the keypad sounder
will sound on a keypad tamper condition.
Keypad Tamper Bell: If enabled, the keypad sounder and bell
will sound on a keypad tamper condition.
No Arm if RF Jam: If selected, when the user tries to arm
No
the system when in a jam condition, the system will provide a
AC/2X
negative acknowledgement and will not arm.
No Arm if Super: If selected, when the user tries to arm the
system and a supervised RF zone is in a supervision condition,
the system will provide a negative acknowledgement and will
not arm.
No AC/2X: If selected, when the user tries to arm the system
with an AC fail condition, the system will provide a negative
acknowledgement and will not arm. To arm the system, the
user must enter their code a second time.
Section 6. System Programming
N/U
L1
L2
L3
Tamper No Arm
L4
Jam
6–33

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents