PROMPT
E N T E R S C H E D N O .
0 0 = Q U I T
0 0
E N T E R E V E N T
NOTE: Events 07 and 10
cause the keypad to
beep every 30 seconds
when messages are
displayed. Stop the
beeps by user code +
OFF.
D E V I C E N U M B E R
X X
G R O U P N U M B E R
X
P A R T I T I O N
X
5-24
VALID ENTRIES
Schedule Number
01-04 = end-user schedules
05-08 = installer-only schedules
[∗] to continue
Enter Event
00 = clear event
01 = Relay On/Off
02 = User Access
03 = Child Not Home Report to
Pager
04 = Auto (Forced) Stay Arm
05 = Auto (Forced) Away Arm
06 = Auto Disarm
07 = Display "Reminder"
08 = Disarm Time Window
11 = Periodic Test Report
††
12 = Up and About
[∗] to continue
Device Number
01-04 = device number
[∗] to continue
Group Number
1-8 = group number
[∗] to continue
Partition
0 = all partitions
1 = partition 1
2 = partition 2
3 = common partition
[∗] to continue
EXPLANATION
Enter the desired schedule number.
Enter the desired event number for event you
want to occur at a specified time.
Event 11 is reserved for the installer only.
Child-Not-Home report (option 03) is sent to all
pagers in the user's partition (message sent is 777-
7777). User must be enabled for paging (see User
Attributes in System Operation section).
Disarm Time Window (08): System can be
disarmed only during this time period. Exception:
If a burglary alarm occurs, the system can be
disarmed outside the scheduled time window.
† A. Auto Stay Arm (event 04) and Auto Away
Arm (event 5) cannot be used if partition 3 is set
as a common partition. To use these scheduling
features, field *30 must be 0, making partition 3
a separate partition.
If either of these options is selected, Forced
Bypass is automatically enabled regardless of
setting in field *23. (the system will
automatically bypass any open burglary zone
when it arms at the scheduled time).
IMPORTANT: Zones left unintentionally open
will be unprotected.
††This selection defines the large time window
within which the time window selected in data
field *85-entry 2 will be monitored.
This prompt appears if event "1" (relay on/off) was
selected, otherwise it is skipped.
Enter the physical device number as programmed
in ∗79 Menu Mode, then press [*] to continue to
the "Start" prompt.
Device numbers 17 and 18 designate built-in
triggers 1 and 2 respectively.
This prompt appears if event "2" (user access) was
selected. Otherwise it is skipped.
Press [*] to continue to the "Start" prompt.
This prompt appears if events "3-8,10" were
selected. Otherwise it is skipped.
Press [*] to continue to the "Start" prompt.