Zone Sounds & Timing
FIELD
TITLE and DATA ENTRIES
Single Alarm Sounding Per Zone
*31
armed period)
0 = no limit on alarm sounding per zone
1 = limit alarm sounding to once per arming
period for a given zone
Fire Alarm Sounder Timeout
*32
0 = yes; fire sounder timeout after time
programmed in field ∗33
1 = no fire sounder timeout; continue sounding
until manually turned off
Siren Timeout
*33
0 = No timeout
1 = 1 min
2 = 2 min
3 = 3 min
Exit Delay
*34
00 - 96 = 0 - 96 seconds
97 = 120 seconds
Entry Delay 1
*35
00 - 96 = 0 - 96 seconds
97 = 120 seconds
98 = 180 seconds
99 = 240 seconds
Entry Delay 2
*36
See *35 above for entries.
Audible Exit Warning
*37
0 = no; 1 = yes
(per
4 = 4 min
5 = 8 min
6 = 16 min
EXPLANATION
Select whether a zone going into alarm should
sound more than once per armed period.
Select whether fire alarm sounding expires after
sounder timeout or remains until manually turned
off.
This field determines whether the external
sounder will shut off after time allotted, or
continue until manually turned off.
The system waits the time entered before arming
entry/exit zones. If the entry/exit door is left open
after this time expires, an alarm will occur or the
zone will be auto-bypassed, depending on the
selection in field *88. Common area zones use
same delay as partition 1.
Upon entering, the system must be disarmed
before the time entered expires, otherwise it
sounds an alarm. Common area zones use same
delay as partition 1.
See *35 for explanation.
Warning sound consists of slow continuous beeps
until last 10 seconds, then it changes to fast beeps.
Sound ends when exit time expires.
Data Field Programming