Mechanics Of Programming - Honeywell ADEMCO VISTA-12A Installation And Setup Manual

Hide thumbs Also See for ADEMCO VISTA-12A:
Table of Contents

Advertisement

Installation and Setup Guide
Zone Type
Type 82
Blockschloss
Types 90-93
Configurable
NOTE: All of the zone types described are available for the wireless portion of the system, if used.

Mechanics of Programming

To program the system from a keypad:
• You must use a 2-line Alpha display keypad.
• All partitions must be disarmed.
Data Field Programming Procedures
Task
Entering Program Mode
Go to a Data Field
3-8
Description
• Used with special Blockschloss lock and key.
• System arms 5 seconds after the key is fully turned (arms MAXIMUM);
key can then be removed.
• When armed, the Blockschloss zone is shorted. An open circuit on this
zone causes trouble condition.
• If zones are "not ready," the key will not turn fully and the system will
not arm.
• Contact ID report code is 409.
• Once the system is armed using Blockschloss, it can be disarmed only by
the key; wired keypads, RF keypads, and keyfobs cannot be used for
disarming.
• If any zone in the system is assigned as Blockschloss zone type, the
system will not arm in AWAY mode. The system can, however, be armed
in STAY or INSTANT modes from keypads and keyfobs even if the
Blockschloss zone is faulted.
• Allows for various custom responses.
• Options include response to entry/exit delays, response to opens/shorts,
types of alarm/trouble sounding, dial delay, and unique Contact ID
report codes.
• Use *83 Menu mode to program these configurable zone types.
Procedure
a) Press both [ ∗ ] and [#] at the same time within 50 seconds after
power is applied to the control,
OR
b) After power-up, enter [Installer code (4-1-1-2)] + 8 0 0 (long beep
indicates one of the partitions is armed and system cannot enter
program mode).
(method "B" is disabled if you exit the program mode using ∗ 98)
Press [ ∗ ] + [Field Number] (for example, ∗ 21).
A display of "EE" or "Entry Error" means you have entered a
nonexistent field. Simply re-enter [ ∗ ] plus a valid field number.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ademco vista-12e

Table of Contents