Menu Mode Programming; About Zone Programming (∗56 And ∗58 Menu Modes); ∗ ∗ ∗ ∗ 56 Zone Programming Procedure - Honeywell ADEMCO VISTA-12A Installation And Setup Manual

Hide thumbs Also See for ADEMCO VISTA-12A:
Table of Contents

Advertisement

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
About Zone Programming (∗ ∗ ∗ ∗ 56 and ∗ ∗ ∗ ∗ 58 Menu Modes)
56 Zone Programming is used to program zones, zone types, report codes, enroll 5800 RF Wireless
Transmitter serial numbers, and identify the type of loop input device(s). This mode can also be used to
enter alpha descriptors for programmed zones; however, we recommend entering descriptors in menu
mode
82 (Alpha Descriptor Programming after all zone programming has been completed).
For a faster method of zone programming, you can use the
56 Zone programming. The
previous experience in programming control panels of this type.
NOTE: Alpha display prompts are shown in a double-line box.
∗ ∗ ∗ ∗ 56 Zone Programming Procedure
Zone Programming involves:
1.
Entering the zone number to be programmed;
2.
Making appropriate entries at the prompts;
3.
Confirming the serial number of wireless transmitter zones.
Start Zone Programming mode by pressing
prompts are displayed:
PROMPT
SET TO CONFIRM?
0 = NO 1 = YES
Enter Zn Num.
(00 = Quit)
17

Menu Mode Programming

58 Expert Programming Mode is designed for those who have had
56 while in Data Programming mode. The following
VALID ENTRIES
Set to Confirm
0 = no
1 = yes
Zone Number
wired zones 01-06,
aux wired zones 17-24
wireless zones 09-24
RF button zones 49-64
91 = addr. device report enable
92 = duress report enable
95, 96, 99 =emergency zones
00 to quit
[∗] to continue
S E C T I O N
58 Expert Programming Mode instead of
EXPLANATION
If 1 (Yes) is entered, the XMIT TO CONFIRM
prompt appears later in this procedure after
entering RF transmitter serial and loop numbers,
and lets you confirm the programming of each RF
transmitter. We recommend that you confirm
every transmitter.
If 0 (No) is entered, the XMIT TO CONFIRM
prompt is automatically skipped.
This option is ignored if programming wired zones
only.
Enter the zone number that you wish to program.
Zone 17 has been entered as an example in the
display at left.
Enter a report code for zone 91 to enable
addressable device reporting.
Enter a report code for zone 92 to enable duress
reporting.
95, 96, 99 are emergency (panic) key zones.
5
5-1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ademco vista-12e

Table of Contents