AUXILIARY DEVICE CURRENT DRAIN WORKSHEET
DEVICE
6128RF Keypad/Transceiver
6150RF Keypad/Transceiver
6148 Fixed-Word Keypad
6150 Fixed-Word Keypad
6160 Alpha Keypad
6150V Fixed-Word Display
Voice Keypad
6160V Alpha Display Voice
Keypad
6164 Keypad w/4-Zone
Expander and Relay
5881 RF Receiver
5883 RF Transceiver
4219 Zone Expander
4204 Relay Unit
4229 Zone Expander/Relay
Unit
TeleCommand
*
*
*If using wired devices such as PIRs or Dual Tecs, refer to the specifications for that particular unit's
current drain.
‡ Figures are for relays OFF/relays ON.
CURRENT
90mA standby/120mA alarm
80mA standby/105mA alarm
30mA standby/55mA alarm
40mA standby/90mA alarm
40mA standby/150mA alarm
60mA standby/160mA alarm
60mA standby/190mA alarm
115mA standby/190mA alarm
35mA
80mA
35mA
15/180mA ‡
35/100mA ‡
55mA (standby)
119mA (local phone)
85mA (remote phone)
(Current available from Aux. terminals = 700mA max.)
Mounting and Wiring the Control
# UNITS
TOTAL CURRENT
TOTAL =
2-7