Honeywell ADEMCO VISTA-12A Installation And Setup Manual page 41

Hide thumbs Also See for ADEMCO VISTA-12A:
Table of Contents

Advertisement

FIELD
TITLE and DATA ENTRIES
Secondary Phone No.
*42
Enter up to 30 digits.
0–9, # + 11 for ' ✱ ', # + 12 for '#', # + 13 for a
pause (2 seconds)
Part. 1 Primary Subs. Acct. No.
*43
Enter digits 0–9; # + 11 for B, # + 12 for C, # +
13 for D, # + 14 for E, # + 15 for F.
Part. 1 Secondary Subs. Acct. No.
*44
Enter digits 0–9; # + 11 for B, # + 12 for C, # +
13 for D, # + 14 for E, # + 15 for F.
Part. 2 Primary Subs. Acct. No.
*45
Enter digits 0–9; # + 11 for B, # + 12 for C, # +
13 for D, # + 14 for E, # + 15 for F.
Part. 2 Secondary Subs. Acct. No.
*46
Enter digits 0–9; # + 11 for B, # + 12 for C, # +
13 for D, # + 14 for E, # + 15 for F.
Phone System Select/Dialer Attempts
*47
Phone System Select:
If Central Station Receiver is not on satellite
link: 0 = Decadic Pulse Dial; 1 = Multifrequency
Tone Dial
If Central Station Receiver is on satellite link: 2
= Decadic Pulse Dial;
3 = Multifrequency Tone Dial
Dialer Attempts: 1 – 10 (for 10, enter #+10)
Report Format (Primary/Secondary)
*48
0 = 3+1, 4+1 ADEMCO L/S STANDARD
1 = 3+1, 4+1 RADIONICS STANDARD
2 = 4+2 ADEMCO L/S STANDARD
3 = 4+2 RADIONICS STANDARD
5 = CID* using 10-digit account number
6 = 4+2 ADEMCO EXPRESS
7 = CID* using 4-digit account number
8 = 3+1, 4+1 ADEMCO L/S EXPANDED
9 = 3+1, 4+1 RADIONICS EXPANDED
10 = ROBOFON 8 (6-digit account number)
11 = ROBOFON Contact ID
Split/Dual Reporting
*49
0 = disable (standard/backup report only).
1 - 5 (see table to right)
EXPLANATION
If you enter fewer than 30 digits, exit by pressing
[∗]. To clear entries from field, press ∗42∗. See
backup reporting note for field ∗41.
Don't fill unused spaces.
Enter up to 10 digits, depending on the report
format selected in field *48. To clear entries from
field, press ∗43∗.
Enter up to 10 digits, depending on the report
format selected in field *48. To clear entries from
field, press ∗44∗.
Enter up to 10 digits, depending on the report
format selected in field *48. To clear entries from
field, press ∗45∗.
Enter up to 10 digits, depending on the report
format selected in field *48. To clear entries from
field, press ∗46∗.
Phone System Select: Select the type of
telephone service.
Dialer Attempts: Enter the number of times the
system should attempt to dial the central station, 1
– 10 times (for 10, enter #+10).
Select report format for primary and secondary
phone numbers.
* ADEMCO Contact ID format
Audio Beeps Format (Follow-Me): To enable the
audio "beeps" format (Follow-Me feature), refer to
the System Features section later in this manual,
and the User Guide.
Special Contact ID Report Codes: The following
three reports are valid only when Contact ID
format is enabled: 412-Successful Download/Access
(see field *53), 461-Wrong Code Entry (see field
*188), and 626-Time/Date Inaccurate (see field
*53).
To Primary No.
Secondary No.
1 = alarms, restore, cancel
2 = all except open/close, test
test
3 = alarms, restore, cancel
4 = all except open/close, test
5 = all
Data Field Programming
To
others
open/close,
all
all
all
4-5

Hide quick links: