About Zone Lists (∗81 Menu Mode) - Honeywell ADEMCO VISTA-12A Installation And Setup Manual

Hide thumbs Also See for ADEMCO VISTA-12A:
Table of Contents

Advertisement

PROMPT
"C"
01 Enter Zn No.
12
01 Output Action
Close for 2 sec
1
Enter Output No.
R02
02
02
A E P TRIG
R02 1 1
3
ZL=1
About Zone Lists (∗ ∗ ∗ ∗ 81 Menu Mode)
Zone lists let you group individual zones for use with certain system actions. The following table shows
the available zone lists and their purposes:
VALID ENTRIES
Zone Number
Output Action
0-6 = see list at right
Output Number
01-04 = output no.
17-18 = on-board triggers
Summary Screen
Used for...
List No.
1,2
general purpose
3
chime-by-zone
4
linked zones
5
night-stay zones
6,7
general purpose
8
final contact set zones or general purpose
9
zones that activate pager 1 or general purpose
10
zones that activate pager 2 or general purpose
11
general purpose
12
exit zones (enabled in field *88)
Menu Mode Programming
EXPLANATION
If zone number was selected, this screen appears.
Enter the desired zone number associated with
this output number.
Press [ ∗ ] to continue.
Enter the zone event that will activate this output.
01 Enter Event
Restore
0
Press [ ∗ ] to continue to the "Output Action"
prompt
Enter the desired device action as listed below.
Press the [ ∗ ] key to continue.
0 = off
Device State
1 = Close for 2 seconds
2 = Close and Stay Closed
3 = Continuous Pulse on & off (1 sec ON, 1 sec
Enter the device output number (programmed in
*79 Menu Mode) you want associated with this
output.
Press [ ∗] to continue.
A summary screen appears showing the
programmed settings.
Press [ ∗ ] to continue.
0 = restore; 1 = alarm
2 = fault;
3 = trouble
4 = Change
5 = Duration 1
(see data field
*177)
6 = Duration 2
(see data field
*177)
OFF)
5-17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ademco vista-12e

Table of Contents