Thermoswitch (Exhaust) - Yamaha VX110 Sport Service Manual

Yamaha waverunner service manual
Table of Contents

Advertisement

+
ELEC
IGNITION SYSTEM

THERMOSWITCH (EXHAUST)

1. Check:
• Thermoswitch (exhaust) continuity
(at the specified temperature)
Out of specification → Replace.
Thermoswitch (exhaust)
continuity temperature:
a 80–86 °C (176–187 °F)
b 66–80 °C (151–176 °F)
1 No continuity
2 Continuity
Checking steps:
• Suspend the thermoswitch (exhaust) in a
container filled with water.
• Place a thermometer in the water.
• Slowly heat the water.
• Measure the continuity when the speci-
fied temperature is reached.
NOTE:
The thermoswitch (exhaust) connector is
black.
7-21
E
È Temperature
É Time

Advertisement

Table of Contents
loading

This manual is also suitable for:

Waverunner vx110 sport

Table of Contents