JET
PUMP
a
1
È
É
IMPELLER DUCT AND DRIVE SHAFT
a
SERVICE POINTS
Drive shaft removal
1. Remove:
• Impeller
NOTE:
Hold the impeller duct assembly in a vise
between two aluminum plates a.
Crankshaft holder:
YB-06552
Crankshaft holder 20:
90890-06552
2. Remove:
• Drive shaft 1
NOTE:
Remove the drive shaft using a press.
3. Remove:
• Rear bearing
Slide hammer and adapters:
YB-06096
Stopper guide plate:
90890-06501
Bearing puller assembly:
90890-06535
Stopper guide stand:
90890-06538
È For USA and Canada
É For worldwide
6-10