Getting Help
Verification
To verify the impedance, enter the show running-config command.
By default, input impedance is 120 ohm. In the following example, the input impedance was successfully
Note
changed to 75 ohm using the line-termination 75-ohm command. Some of the configuration has been
deleted for readability.
Router# show running-config
Building configuration...
Current configuration:
.
.
.
!
controller E1 0
clock source free-running
line-termination 75-ohm
pri-group timeslots 1-31
!
.
.
.
Router#